TM 10-4610-215-10
TM 08580A-10/1
Table 2-3. Operator/Crew Preventive Maintenance Checks and Services
(Unit) (Continued)
B - Before
D -During
A - A f t er
W - Weekly
For readiness reporting
Interval
Procedures
Equipment Is not
Item
Item to be
Check for and have repaired
ready/available
No.
B D A
W
inspected
or adjusted as necessary
if:
Do not operate ROWPU with an
open control box assembly; it can
kill you.
Inspect the plug connectors,
toggle switches, and lamps for
loose mountings and bad parts.
Replace lamps that dont work.
See that the junction box is
securely mounted and kept
closed.
20
R.O. pump drive
Inspect belt guard for loose
Belt guard off or
belt guard
mounting bolts. Tighten all
hanging.
studs, nuts, and capscrews.
21
R.O. Pump drive
Check all five V-belts for
Belt tension re-
belts
cracks, rubbing, and signs
quires adjustment;
of wear. Check belt ten-
belts are defec-
sion: You should be able to
tive.
push belts down only a half-
inch at center of span.
22
R.O. pump, wiring,
Inspect wire connection go-
motor mounts,
ing to junction box. ln-
head gasket
spect the motor mounts for
and piping
cracks or breaks. Look for
dirt, corrosion, or water
damage. Check for head gas-
ket leaks and piping leaks.
PD-680 is potentially
dangerous. Avoid repeated and
prolonged breathing of vapors
and skin contact with the liquid.
Do not use near open flame,
arcing equipment or other ignition
sources. Always wear protective
clothing and eyewear.
2-23