TM 10-4610-215-10
TM 08580A10/1
Table 2-3. Operator/Crew Preventive Maintenance Checks and Services
(Unit) (Continued)
B - Before
D During
A After
W Weekly
For readiness reporting
Interval
Procedures
Equipment is not
Item
Item to be
Check for and have repaired
ready/avaiIable
No.
B
D A
W
inspected
or adjusted as necessary
if:
Water leaking into the cavity past
the seals (packing) is normal. The
pump is designed such that
accumulated water will be drained
from the cavity through the plastic
drain tube to the ground. However,
as the packing and plungers wear
from normal operation, the water
leakage will become more severe.
When the drain tube can no longer
accommodate the flow, the cavity
will fill with water, which could enter
the crankcase and contaminate the
oil.
If the water level rises near the
plungers, the packing and the
plungers, if scored, must be
replaced. Report this condition to
unit maintenance.
26
Low- and high-
Inspect for dust or dirt.
Toggle switches
pressure switches
Inspect for loose or damaged
are broken.
and toggle switches
wires.
Switch cases are
Report loose or damaged
broken. Bare wires
wires to unit maintenance.
are visible.
27
Pump assemblies
Inspect the pumps for loose
Raw water pumps or
mountings, damaged frames,
booster pump do
cracked housings, and leaky
not work.
seals.
Inspect pumps for unobstructed,
clockwise rotation.
Listen for unusual noises
from pumps or pump motors
during operation.
28
Cable assemblies
Inspect electrical cable assemblies
Cables are broken
for cracked, broken or cut insulation
or bare wires are
Inspect connectors on ends
visible.
of cables.
Report any unserviceable
cable assembly to unit
maintenance.
225