TM 10-4610-215-10
TM 08580A-10/1
Table 2-3. Operator/Crew Preventive Maintenance Checks and Services
(Unit) (Continued)
B - Before
D During
A After
W Weekly
For readiness reporting
Interval
Procedures
Equipment is not
tern
Item to be
Check for and have repaired
ready/available
No.
B D A
W
inspected
or adjusted as necessary
if:
23
R.O. Pump Motor
Wipe motor with a clean
cloth dampened with an ap-
proved cleaning solvent
(P-D-680).
Check oil level and Iubri-
cate in accordance with lu-
bricating order, LO 10-
4610215-12/Ll 08580A12
Inspect for signs of over-
heating or too much wear.
NOTE
A new pump may run hotter for a
few days. Change oil before first
startup; watch oil level during
breakin period.
Listen for uneven, knocking
Motor makes un-
sound.
familiar sounds
during operation.
24
R.O. Pump drain
Inspect drain tube end to
Drain clogged and
tube end
ensure that drain is open.
cannot be cleared.
Open restricted drain.
25
R.O. Pump cavity
Remove the wing nut and cover
seals and plungers
plate which are located at the top
center of pump. Plungers equipped
with rubber splash guards are now
exposed. Using spanner wrench
from storage box, tighten packing
nut.
Inspect R.O. pump cavity to
Water level in R.O.
make sure excessive leakage
pump cavity rises
is not occurring:
near plungers dur-
ing operation.
CAUTION
Excessive leakage will contami-
nate the oil and score the
plungers.
2-24