TM 10-4610-215-24
TM 08580A-24/2
(17) Remove pump-end plate (14) from rotor shaft (15).
CAUTION
Motor casing wiring can be snagged or broken by rotor shaft.
Take care not to damage wires when removing rotor shaft.
(18) Remove rotor shaft (15) from motor casing (27).
(19) Using a bearing press/puller, remove pump-end bearings (16) from rotor shaft (15).
(20) Remove bearing snap ring (17) from rotor shaft (15).
(21) Using a bearing press/puller, remove fan-end bearings (18) from rotor shaft (15).
(22) Remove bearing snap ring (19) and snap ring (20) in front of centrifugal mechanism (21) from rotor
shaft (15).
(23) Remove centrifugal mechanism (21) from rotor shaft (15).
(24) Remove two screws (22) from inside motor casing (27) and stationary switch (23).
(25) Disconnect two wire clips from stationary switch (23) and remove stationary switch (23) from motor
casing (27).
(26) Remove two screws (24) from motor casing (27) and capacitor cover (25).
(27) Remove capacitor cover (25) from motor casing (27).
(28) Disconnect two wire clips from capacitor (26) and remove capacitor (26) from motor casing (27).
c. Motor Disassembly. (Figure 310) (USMC)
(1) To remove motor from pump assembly refer to paragraph 2-48.
WARNING
Objects blown by compressed air can cause serious eye injury
Always wear protective goggles when using compressed air.
3-42