TM 10-4610-215-24
TM 08580A-24/2
CAUTION
(13).
d
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25)
(26)
Motor casing wiring can be snagged or broken by rotor shaft.
Take care not to damage wires when removing rotor shaft.
Remove pump-end plate (13) with rotor shaft (10) attached, from motor casing (8).
Remove two screws (16) and two washers (17) from bearing retainer plate (18) and pump-end plate
Remove pump-end plate (13) from rotor shaft (10).
Remove shaft seal (19) from rotor shaft (10).
Use a bearing puller/press to remove bearing (20) from rotor shaft (10).
Remove bearing retainer plate (18) from rotor shaft (10).
Use a bearing puller/press to remove front-end bearing (21) from rotor shaft (10).
Remove centrifugal mechanism (22) from rotor shaft (10).
Remove two screws (23) from motor casing (8) and stationary switch (24).
Disconnect two wire clips from stationary switch (24) and remove switch (24) from motor casing (8).
Remove two screws (25) from motor casing (8), gasket (27), and capacitor cover (26).
Remove capacitor cover (26) and gasket (27) from motor casing (8). Discard gasket (27).
Disconnect two wire clips from capacitor (28) and remove capacitor (28) from motor casing (8).
WARNING
Objects blown by compressed air can cause serious injury.
Always wear protective goggles when using compressed air.
(1) Blow out dirt inside motor casing with compressed air.
3-45
Cleaning.