TM 10-4610-215-24
TM 08580A-24/2
(2)
Before moving motor to work area, blow dirt off motor.
WARNING
Drycleanlng solvent Fed. Spec. P-D-680 is potentially
dangerous. Avoid repeated and prolonged breathing of vapors
and skin contact. Do not use near open flame, arcing equipment
or other ignition sources. Always wear protective clothing and
eyewear.
Clean motor using a stiff brush and solvent Fed. Spec. P-D-680.
Allow to air dry.
Move motor to work area.
Remove four screws (1) from conduit box (5), gasket (3), and conduit box cover (2).
Remove conduit box cover (2) and gasket (3) from conduit box (5). Discard gasket (3).
Remove two screws (4) from motor casing (8), gaskets (6), spacer (7), and conduit box (5).
Remove conduit box (5), gaskets (6), and spacer (7) from motor casing (8). Discard gaskets (6).
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10) Remove shaft key (9) from rotor shaft (10).
NOTE
Mark frontend plate, pump-end plate, and motor casing with
matching punch pricks for ease of reassembly.
(11) Remove four through-bolts (11) and eight washers (12) from pump-end plate (13), motor casing (8),
and frontend plate (14).
(12) Remove front-end plate (14) from motor casing (8).
(13) Remove spacer (15) from front-end plate (14) or rotor shaft (10).
3-44