TM 10-4610-229-10
2-4.
ASSEMBLY AND PREPARATION FOR USE (CONT)
4
Remove two end clamp bolts, two nuts, and two end clamp halves. Set aside for installation.
5
Gently work end cap assembly back and forth to remove from pressure tube. Set aside in a
clean place. Go to other (feedwater) end of pressure tube. 6 Loosen rigid tube nut at manifold.
DO NOT remove. Remove rigid tube nut from end cap assembly. Swing tube away from end
cap assembly.
6
Loosen rigid tube nut at manifold. DO NOT remove. Remove rigid tube nut from end cap
assembly. Swing tube away from end cap assembly.
2-87