TM 10-4610-229-24
2-69. CAGE PANEL ASSEMBLY REPLACEMENT/REPAIR (CONT)
2
Tag and remove two pressure gage lines from switch.
3
Remove conduit from switch.
4
Tag and disconnect two wires.
CAUTION
To prevent switch from dropping, be sure to support it when removing screws.
5
Hold switch and remove two screws and lockwashers. Remove switch.
6
Install switch. Install two lockwashers and screws.
7
Connect two wires. Remove tags.
8
Install conduit on switch.
9
Install two pressure gage lines. Remove tags.
10
Plug in pretreatment assembly power cable.
e. Pressure Indicator Gage Replacement
NOTE
Procedures for replacement of pressure indicator gages PI-1, PI-2, and PI-3 are the same.
1
Remove pressure gage line from rear of gage.
2-168