TM 10-4610-229-24
2-79. INSTRUMENT PANEL ASSEMBLY REPAIR (CONT)
e.
Fuel Level Gage Replacement
1
Remove two screws and lockwashers. Remove upper rear cover.
WARNING
To prevent electric shock, make sure battery is disconnected before performing this procedure.
2
Tag two wires. Remove two nuts and flatwashers. Remove wires.
3
Remove two nuts, lockwashers, and metal bracket.
4
Pull fuel gage through front of panel.
5
Remove resistor from back of gage.
6
Install resistor in back of gage.
7
Install fuel gage. Install bracket, two washers, and nuts.
8
Install two wires. Install two lockwashers and nuts. Remove tags.
9 Install upper rear cover. Install two lockwashers and screws.
10
Connect battery (para 2-16).
2-205