TM 10-4610-229-24
2-114. SAMPLE VALVE ASSEMBLY REPLACEMENT/REPAIR (CONT)
3 Install sample valve assembly in pressure tube.
4
Connect product tube and discharge tube.
2-115. PRODUCT TUBE ASSEMBLY REPLACEMENT/REPAIR
This task covers:
a.
Removal
c. Assembly
b.
Disassembly
d. Installation
INITIAL SETUP
Use With
Tools
Reverse Osmosis Block Assembly
General Mechanic's Automotive Tool
Kit, item 10, appendix B
a. Removal
1
Unscrew line nut on each end of tube assembly.
2
Remove tube.
b. Disassembly
1
Remove O-ring, rubber grommet, metallic clip, and line nut.
2-282