2-113. PRODUCT SPOOL ASSEMBLY REPLACEMENT/REPAIR (CONT)
12
Install flowmeter in vise.
13
Install reducer and nipple.
14
Install elbow on nipple.
15
Install check valve with quick-disconnect coupling assembly in elbow.
d. Installation
NOTE
Two persons required for next two steps.
1
Have one person support weight of product spool assembly. Install hold-down clamp. Install screw and nut.
2
Aline T-pipe with connection.
3
Apply thin coat of silicone lubricant to gasket lips and outside of gasket.
4
Place gasket over end of elbow pipe, being sure it doesn't overhang end of connection.
5 Aline end of pipe with elbow pipe. Slide gasket to center position between grooves. No portion of gasket should
overhang grooves.
6
Place coupling halves over gasket, making sure keys are in grooves.
7
Install two bolts. Place nuts on bolts and hand-tighten.
CAUTION
Overtightening nuts may cause gasket to pinch. Tighten nuts only until coupling halves are firmly
together (metal-to-metal).
8
Tighten nuts alternately and equally until coupling halves are firmly together.
2-280