TM 10-4610-229-24
2-120. DISCONNECT ADAPTER REPLACEMENT (CONT)
a. Removal
1
Disconnect threaded hose from adapter.
2
Remove two nuts, bolts, coupling halves, and gasket. Remove adapter.
b. Installation
1
Check gasket for damage. Replace as required.
2
Apply thin coat of silicone lubricant to gasket lips and outside of gasket.
3
Place gasket over end of adapter, being sure it doesn't overhang end of connection.
4
Aline end of high pressure hose with adapter. Slide gasket to center position between grooves. No portion of
gasket should overhang grooves.
5
Place coupling halves over gasket, making sure keys are in grooves.
6
Install two bolts. Place nuts on bolts and hand-tighten.
2-294