TM 10-4610-229-24
3-26. BOOST PUMP ASSEMBLY REPAIR (CONT)
4
Set dial indicator to 0.
5
Observing gage, turn stainless steel shaft one complete revolution.
NOTE
If reading is less than 0.003 in., go to step 1.0.
6
Rotate stainless steel shaft until highest reading is obtained.
7
Loosen four bolts holding intermediate housing.
8
Rotate intermediate housing until 0.003 in. or less is obtained. Tighten bolts.
9
Repeat step 5.
10
Set pointer of dial indicator on intermediate housing facing.
11
Observing gage, turn stainless steel shaft one complete revolution.
NOTE
If reading is less than 0.003 in., go to step 16.
12
Remove four bolts, lockwashers, and nuts. Remove intermediate housing.
13
Install shim.
14 Install intermediate housing. Install four nuts, lockwashers, and bolts.
15
Repeat step 11.
16
Remove dial indicator. Remove wrapping from stainless steel shaft.
17
Install gasket, flange, retainer, and stationary seal.
18
Aline flange and intermediate housing bolt holes. Install six lockwashers and socket-head screws.