TM 10-4610-229-242-16. BATTERY/BATTERY BOX REPLACEMENT (CONT)HighPressurePumpAssemblyWARNING· To prevent injury to personnel from electric shock, be very careful when disconnecting batterycables.· Fumes from battery acid may cause explosion. To prevent explosion, keep sparks and openflame away from battery.· If battery acid gets on skin or eyes, wash with water right away. Get medical help.1Remove two battery cover mounting nuts, lockwashers, and flatwashers. Remove battery cover.2Remove two battery terminal nuts. Remove two wires leading to plug socket.3Reinstall two battery terminal nuts. Do not tighten.4Loosen remaining battery terminal nuts. Disconnect battery cables.5Remove two nuts, lockwashers, and flatwashers. Remove battery retainer.6Remove batteries.2-43