TM 10-4610-229-24
2-16. BATTERY/BATTERY BOX REPLACEMENT (CONT)
High Pressure Pump Assembly
WARNING
· To prevent injury to personnel from electric shock, be very careful when disconnecting battery
cables.
· Fumes from battery acid may cause explosion. To prevent explosion, keep sparks and open
flame away from battery.
· If battery acid gets on skin or eyes, wash with water right away. Get medical help.
1
Remove two battery cover mounting nuts, lockwashers, and flatwashers. Remove battery cover.
2
Remove two battery terminal nuts. Remove two wires leading to plug socket.
3
Reinstall two battery terminal nuts. Do not tighten.
4
Loosen remaining battery terminal nuts. Disconnect battery cables.
5
Remove two nuts, lockwashers, and flatwashers. Remove battery retainer.
6
Remove batteries.
2-43