2-18. INSTRUMENT PANEL REPAIR (CONT)
8
Connect wire to temperature gage.
9
Route temperature tube back to temperature sensor mounting.
10
Install temperature sensor. Tighten line nut.
11
For raw water pump assembly: Install air shrouds (para 2-34).
12
Install wire ties.
13
Aline holes on instrument panel and mounting bracket. Install four flatwashers, bolts, lockwashers, and nuts.
14
Connect battery (para 2-16).
b.
Battery Indicator Gage Replacement
1
Remove four nuts, lockwashers, bolts, and flatwashers. Remove instrument panel from mounting bracket.
WARNING
To prevent electric shock, make sure battery is disconnected.
2
Tag and disconnect two wires.
3
Remove two nuts, lockwashers, and retaining bracket. Remove gage from front of panel.
4
Install battery indicator gage on studs. Install retaining bracket, two lockwashers, and nuts.
2-50