TM 10-4610-229-242-18. INSTRUMENT PANEL REPAIR (CONT)10Connect battery (para 2-16).f.RelaySwitch/FuseReplacement1Remove four nuts, lockwashers, bolts, and flatwashers. Remove instrument panel from mounting bracket.NOTEPerform steps 2 and 7 only when replacing fuse.2Remove fuse from relay switch. If replacing fuse only, go to step 7.3Remove boot, nut, starwasher, and nameplate. Pull switch from rear of panel.WARNINGTo prevent electric shock, make sure battery is disconnected.4Tag and remove four wires. Remove switch.5Install switch. Install nameplate, starwasher, nut, and boot.6Connect wires and remove tags.7Install fuse in relay switch as required.2-54