TM 10-4610-229-24
2-28. OIL BATH AIR FILTER REPLACEMENT/REPAIR (CONT)
a.
Removal
1
Remove two nuts and lockwashers. Remove air filter housing.
2
Remove and discard gasket.
b.
Disassembly
1
Loosen screw and remove top.
2
Loosen clamp on side of filter. Remove bottom housing and clamp.
3
Remove and service filter element. (See TM 104610-229-10.)
2-77