TM 10-4610-232-34
Figure 2-20. Electrical Installation (sheet 3 of 4)
(3) Tag and disconnect the cable at the CO monitor by opening CO monitor door and tagging and disconnecting all
wires. Refer to para 2-56 for procedure.
e. Refer to sheet 3 and remove cable (W70) as follows:
(1) Tag and disconnect cable at the 24 VDC power supply (para. 2-53).
(2) Cut tie wraps which secure the cable to the ceiling and walls of the ROWPU.
(3) Tag and disconnect cable at the CO monitor by opening CO monitor door and tagging and disconnecting all
wires. Refer to para. 2-56.
f. Refer to sheet 3 and remove cable (W29) as follows:
(1) Tag and disconnect cable (W29) at the main control panel (para. 2-21).
(2) Cut tie wraps which secure the cable to the ROWPU.
(3) Disconnect the cable at the distribution pump external electrical panel assembly (TM 10-4610-232-12, para.
4-35).
2-106