TM 10-4610-232-34
WARNING
The main control panel is heavy. Do not attempt to move it without adequate
personnel and lifting equipment. Serious injury and damage to the equipment could
result if this precaution is not observed.
a. Using suitable lifting device, place the main control panel in the doorway to the ROWPU.
b. Position two personnel on each side of the control panel and walk the panel into position on the floor of the
ROWPU.
c. Tilt the control panel as required and install vibration pads (29) beneath the panel.
d. Secure the control panel to the floor using four capscrews (26), Iockwashers (27) and washers (28).
e. Install capscrew (21), washer (22), nut (23), Iockwasher (24) and washer (25) to secure the right hand side of the
control panel to the accessory table.
f. Install three capscrews (16), washers (17 and 20), Iockwashers (19) and nuts (18) to secure the control panel to the
divider panel.
g. Install the two control panel support bars (11) and two vibration pads (15) with two capscrews (12), washers (14)
and nuts (13).
h. Reconnect the tubing (9) to pressure switch (10).
i. Install four floor mounted tie down clamps (7) using pop rivets (8).
j. Install door holder(6) and secure with three capscrews (1), Iockwashers (2), washers (3), connector (4) and eyebolt
(5).
3-4