TM 10-4610-239-24
TM 08580B-24/3
REMOVAL. (Cont)
i.
Remove four screws (19), lockwashers (20), flat washers (21), and bushings (22).
CAUTION
Removal of cartridge filter requires the use of a crane rated at 1 ton
(0.91 tonne) or greater in order to prevent damage to equipment.
j.
Using lifting equipment and two assistants, tilt cartridge filter (23) and remove it from ROWPU.
k.
Remove two gasket halves (24) from ROWPU deck.
1.
Remove elbow (26), nipple (28), and adapter (29).
INSTALLATION.
NOTE
Apply antiseize tape to pipe threads before installation.
a.
Install adapter (29), elbow (26), and nipple (28).
b.
Position two gasket halves (24) on ROWPU deck. Align holes with threaded inserts on ROWPU frame.
CAUTION
Installation of cartridge filter requires the use of a crane rated at 1 ton
(0.91 tonne) or greater in order to prevent damage to equipment.
c.
Using lifting equipment and two assistants, lift cartridge filter (23) and position on ROWPU.
Align mounting holes with holes in gasket halves (24).
d.
Install four bushings (22), four flat washers (21), four lockwashers (20), and four screws (19).
e.
Position bracket (18) and install two screws (17), two lockwashers (16), and two nuts (15).
f.
Install elbow (25) and adapter (27).
g.
Install flexible tubing (14) on nipple (28) and tighten hose clamp (13).
h.
Position pipe section with nipple (12) and tighten nut (11).
i.
Install three gaskets (10), three clamps (9), six screws (8), and six nuts (7).
j.
Install tubing (5) on elbow and adapter (6).
k.
Install flexible tubing (4) on nipple (30) and tighten hose clamp (3).
l.
Install flexible tubing (2) and tighten quick-disconnect (1).
2-171