TM 10-4610-239-24
TM 08580B-24/3
ASSEMBLY.
NOTE
There are two end plate assemblies on each of four R.O.
pressure tubes. Procedure for both end plates and all tubes
are the same.
Coat O-rings and O-ring path with a thin layer of silicone
grease to reduce friction during installation.
a. Install filter elements. (Refer to TM 10-4610-239-10).
b. Install concentrate port (17) into end plate (4).
c.
Install new retaining ring (16) on concentrate port (17).
d. Install O-ring (15) and adapter (14) on permeate port (8).
e. Install O-rings (12) and (13) on sealing plate (5).
f.
Insert permeate port (8) through sealing plate (5) and end plate (4) and installnew retaining ring (7) on
permeate port (8).
NOTE
The two O-rings in the end connector have different outside
diameters. Feel inside end connector find the large and small
inside-diameter ends. Install large O-ring in large end of end
connector. Install small O-ring in small end of end connector.
g. Install all O-rings (10) and (11) in connector(9).
h. Install end connector (9) on permeate port (8).
NOTE
Small inside diameter end of end connector goes in permeate
port.
j.
Install capscrews (6) into end plate (4) and sealing plate (5).
k.
Install end plate assembly (4) onto pressure tube (3).
CAUTION
Unequal torque on any end cap nut can result in damage to
equipment.
1. Install flatwashers (2) and nuts (1) onto studs on pressure tubes (3).
(73.5N.m) in sequence A through J as shown.
2-217