TM 10-4610-239-24
TM 08580B-24/3
REMOVAL.
TOGGLE SWITCHES
NOTE
There are 11 toggle switches. The number of wires attached to each switch
may vary depending on use. All switches are removed the same. One is
shown.
Tag all wires before removal.
a. Remove 14 screws (1), lockwashers (2), and flat washers (3). Lower control box cover (4).
b. From inside control box assembly, remove two screws (5) and remove wires (6).
c.
From front of control box assembly, remove mounting nut (7) and O-ring seal (8).
d. Remove lockring (9) and switch body (10).
e. Close control box cover (4) and install but do not tighten 14 screws (1), lockwashers (2), and flat
washers (3).
EMERGENCY STOP SWITCH
a. Remove 14 screws (1), lockwashers (2), and flat washers (3). Lower control box cover (4).
b. Remove cap (11), locknut (12), keyway washer (13), and fiber washer (14) from switch body (15).
c.
Remove four screws (16) and remove wires (17).
d. Remove switch body (15) and rubber washer (18).
e. Close control box cover (4) and install but do not tighten 14 screws (1), lockwashers (2), and flat
washers (3).
INSTALLATION.
TOGGLE SWITCHES
NOTE
There are 11 toggle switches. The number of wires attached to each switch
may vary depending on use. All switches are installed the same. One is
shown.
a. Remove 14 screws (1), lockwashers (2), and flat-washers (3). Lower control box cover (4).
b. Install lockring (9) and position switch body (10) in control box assembly.
c.
Install O-ring seal (8) and mounting nut (7).
d. Install wires (6) as tagged and two screws (5).
e. Close control box cover (4) and install but do not tighten 14 screws (1), lockwashers (2), and flat
washers (3).
3-167