TM 10-4610-241-24
TO 40W4-13-42
3-53.
JUNCTION BOX ASSEMBLY REPAIR - continued.
(3) Terminal boards and jumpers.
NOTE
This procedure covers installation of TB2 Installation of other terminal boards is similar.
(a) Position information plate (54) and circuit board TB-2 (53) on junction box as indicated.
(b) Secure circuit board (52) to floor of junction box with screws (52), flatwashers (51), lockwashers (50) and
nuts (49).
NOTE
Install wires as tagged If tags or missing or illegible, refer to electrical connection
diagram in Appendix F of this manual or data plate on back of junction box door.
(c) Connect wires to terminal board as tagged during disassembly or use electrical connection diagram.
3-311