ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0005 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
PREPARATION FOR USE AND INSTALLATION INSTRUCTIONS
EQUIPMENT OFF-LOADING ARMY UNIT
5. Assemble the deck supports by sliding a horizontal section onto each pad section and securing it
with the retaining pin (Figure 7).
HORIZONTAL SECTION
RETAINING PIN
PAD SECTION
Figure 7. Deck Support Assembly.
6. With another person lifting up on the deck, slide the support assemblies into the brackets on the
deck and secure them with the retaining pins.
7. Lower the deck until the support assembly pads are on the ground. Adjust the height of individual
assemblies as necessary until the deck is level and all four pads are on the ground.
WARNING
Packed-out items can shift during transport and may fall out when the top panel is
opened. To prevent personal injury, be careful when opening the panel.
8. Unlatch and lift up the top panel. With another person holding the panel open and horizontal,
insert the retaining pins into the panel supports to lock it in position.
9. Remove the tie-down straps securing the packed-out items on the skid and flat rack.
NOTE
Do not remove the two straps that secure the NBC tank.
10. Remove the cargo cover from the generator area.
0005 00-7