ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0005 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
PREPARATION FOR USE AND INSTALLATION INSTRUCTIONS
EQUIPMENT OFF-LOADING ARMY UNIT
1. Remove the items packed out on top of the four BII boxes.
WARNING
Two person lift. Two people are required to safely move the BII boxes and pump
skids. Lift with your legs, not your back. Failure to observe this warning may
result in back injury.
Chemical dust. If any chemical buckets or chemical packets are broken and
chemical dust is present, wear a dust mask, a protective face shield, and chemical
gloves when handling. Avoid inhaling chemical dust or fumes. Failure to observe
this warning may result in mild irritation of the nose, throat, eyes, and skin.
Liquid chemicals. If any liquid chemical containers are broken, wear a protective
face shield, chemical gloves, and a chemical apron when handling. Keep water
ready when handling. Avoid contact with the liquid. Failure to observe this
warning may result in chemical burns, or severe irritation of the nose, throat, eyes,
and skin.
NOTE
The caustic cleaner liquid (sodium hydroxide) in the four bottles in BII Box #5
solidifies at temperatures of 53 degrees F and lower. The caustic must be stored
in a location warmer than 53 degrees F.
2.
Remove the four BII boxes.
3.
Remove the hose heating blankets and pump skid covers.
4.
Remove the priming pitcher from inside the pump skid.
5.
Remove the pump skid retaining rods. Store them in the framework at the end of the flat rack.
6.
Remove the pump skids.
7.
Remove the remaining items from the operator station area.
0005 00-9