ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0007 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
PREPARATION FOR USE AND INSTALLATION INSTRUCTIONS
SET-UP OPERATION UNDER USUAL CONDITIONS
WARNING
Electrical hazard. The TWPS operates on 416 Volts AC.
Making electrical
connections to the TWPS power distribution panel must be coordinated with the
procedures for establishing electrical power to the TWPS. Do NOT connect the
Motor-Driven Pump P-2 electrical power cable at this time. Failure to observe this
warning may result in serious injury or death from electrocution.
P-2 PUMP OR P1 PUMP ONLY CONFIGURATION DEPLOYMENT
CAUTION
Potential water damage to equipment. Make note of potential tidal or river flood
conditions and keep the raw water pump located beyond the reach of the water.
Failure to observe this caution may result in water damage to the pump and motor.
1. Position the raw water pump as follows (see Figure 3 and Figure 4):
WARNING
Three person lift. Three people are required to safely lift Diesel-Driven Raw Water
Pump Skid P-1. Lift with your legs, not your back. Failure to observe this warning
may result in back injury.
Two person lift. Two people are required to safely lift Motor-Driven Raw Water
Pump Skid P-2. Lift with your legs, not your back. Failure to observe this warning
may result in back injury.
a. Move Motor-Driven Pump Skid P-2 or Diesel-Driven Pump Skid P-1 into place.
b. Place the pump skid on solid footing and as nearly level as possible.
A-02
A-01
A-05
PRIMING
VENT HOSE
2 X 10 S-HOSE
P-2
2 X 50 D-HOSE
Figure 3. P-2 Pump Only Configuration Deployment.
0007 00-6