ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0007 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
PREPARATION FOR USE AND INSTALLATION INSTRUCTIONS
SET-UP OPERATION UNDER USUAL CONDITIONS
A-01
A-02
A-05
PRIMING
VENT HOSE
2 X 10 S-HOSE
2 X 50 D-HOSE
P-1
Figure 4. P-1 Pump Only Configuration Deployment.
c.
If Diesel-Driven Pump P-1 is used, place an absorbent pad under it for environmental
protection in the event of a fuel spill and install the fuel tank as follows (see Figure 2):
1) Set the fuel tank assembly on the pump skid
2) Connect the red-banded fuel tank fuel supply hose to the red-banded engine fuel
supply hose with the quick-connect fittings.
3) Connect the yellow-banded fuel tank return hose to the yellow-banded engine
fuel return hose with the quick-connect fittings.
2. Connect the raw water adaptors and hoses as follows:
WARNING
Health hazard. Do not attempt to use product water hoses to handle raw water or
raw water hoses to handle product water. When installed with the proper adaptors
as directed, the hoses cannot be interchanged. Failure to observe this warning
and mixing hoses could cause contamination of water resulting in serious illness.
a. Collect the following hoses and adaptor assemblies:
1) One to two 2 in. x 50 ft., green-banded raw water discharge hoses.
2) One 2 in. x 10 ft., green-banded raw water suction hose.
3) Adaptor assemblies A-01, A-02, and A-05.
4) One 1 in. x 5 ft., clear plastic priming vent hose.
b. Inspect gaskets in the female ends of the hoses. Replace damaged or missing gaskets.
0007 00-7