ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0007 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
PREPARATION FOR USE AND INSTALLATION INSTRUCTIONS
SET-UP OPERATION UNDER USUAL CONDITIONS
NOTE
When installing Adaptor A-01 the bolt on the check valve must be oriented in a
vertical position. Failure to observe this note may limit the effectiveness of the
check valve and result in an inability to maintain prime.
The support strap on Adaptor A-01 must be oriented near the top of the adaptor
and firmly secured to the pump frame to make sure air does not leak into the
adaptor. Failure to observe this note may result in a reduced pumping capacity or
an inability to maintain prime.
c.
Attach Adaptor A-01 to the suction inlet of the raw water pump. Loop the strap over the
pump frame crossbar and tighten to a slight tension.
d.
Attach Adaptor A-02 to the discharge outlet of the raw water pump.
e.
Connect the priming vent hose to Adaptor A-02.
f.
Connect, as needed to reach the MF Feed Tank, one or two 2 in. x 50 ft., green-banded
discharge hoses to Adaptor A-02 at the discharge outlet of the raw water pump.
g.
Connect Adaptor A-05 to the end of the discharge hose that is coming from Adaptor A-
02.
h.
Connect the 2 in. x 10 ft., green-banded suction hose to Adaptor A-05.
WARNING
Electrical hazard. The TWPS operates on 416 Volts AC.
Making electrical
connections to the TWPS power distribution panel must be coordinated with the
procedures for establishing electrical power to the TWPS. If Motor-Driven Pump P-
2 is used, do NOT connect its electrical power cable at this time. Failure to
observe this warning may result in serious injury or death from electrocution.
SODIUM BISULFITE SYSTEM SET-UP
CAUTION
Potential for damage to the MF elements and RO membranes. Chlorine will
destroy the MF elements and RO membranes. If the raw water source is
chlorinated, sodium bisulfite must be mixed into the raw water before it is pumped
into the MF feed tank. Sodium bisulfite neutralizes the chlorine. Failure to observe
this caution will result in the destruction of the MF elements and RO membranes.
The sodium bisulfite system MUST be set up before chlorinated raw water is pumped into the MF Feed
Tank. The instructions for setting up the sodium bisulfite system are described in WP 0010, Other Set-
Ups Operation Under Unusual Conditions.
0007 00-8