ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0007 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
PREPARATION FOR USE AND INSTALLATION INSTRUCTIONS
SET-UP OPERATION UNDER USUAL CONDITIONS
FLOATING INLET STRAINER
SHACKLE
3 X 10 S-HOSE
PULLEY
SHACKLE
3 IN. PLUG
ANCHOR
Figure 5. Anchor, Rope, Inlet Strainer, and Hoses Assembled On-Shore.
3. Deploy the anchor as follows:
WARNING
Potential for physical injury. Crew members other than those deploying the
anchor must stand clear when the anchor is being deployed. Failure to observe
this warning may result in serious injury if a person is hit with the anchor.
a.
Gain good footing near the water's edge.
b.
Make sure the rope is free to play out.
c.
Throw the anchor underhand into the water source.
d.
At beach sites, walk or carry the anchor to the desired location about 30 feet past the
desired location of the inlet strainer.
e. Pull slowly on the rope and feel for the anchor to grab. If it does not grab, repeat the
anchor deployment throwing it into an adjacent location.
NOTE
The anchor may be deployed by boat if available and if water conditions allow.
Appropriate water safety precautions, such as the use of life jackets or vests, must
be observed.
4.
Complete the raw water hose connections as follows (see Figure 6):
a. Untie the free end of the rope from the suction hose.
b. One crew-member pulls the free end of the rope as another feeds out the inlet strainer
and suction hose into the water.
c. When the inlet strainer is in the desired position, uncap the hose end and the hose will
sink.
d. Tie the free end of the anchor rope to the raw water pump frame to secure the anchor.
e. Connect the uncapped end of the raw water suction hose to Adaptor A-01 at the raw
water pump inlet.
0007 00-10