ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0035 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
TROUBLESHOOTING PROCEDURES
UNIT TROUBLESHOOTING - TWPS CONTROL SYSTEMS
Table 2. OCP Display and Instrument Loop Troubleshooting Continued.
ITEM
MALFUNCTION
POSSIBLE CAUSES
CORRECTIVE ACTION
12
Product flow reading is not as
7)
If the display is very unsteady while the
cont.
expected from previous
TWPS is operating normally, replace
operational data (continued).
With the TWPS in STANDBY, open the
FT-501 output failure.
Instrument/Solenoid Panel and set the flow
1) Press the MAIN MENU key. Use the
up/down arrows to display the
TEST/MAINT screen.
2) Press ENTER key to display the
STATUS screen.
3) Press the down arrow until the
OUTPUT screen appears.
4) Press ENTER key to display OUTPUT?
XX.XX mA
5) Use the arrows to change the display to
20.00 mA.
6) When the steps below are completed,
press MENU and then ESC to return to
the normal display screen.
Open the OCP display panel to expose the
FT-501 output failure (continued).
PLC. Locate the slot 11 input card. Open
the wire way cover and locate terminal C4+.
Remove the wire and turn the terminal screw
back in. Measure the mA (4-20mA) between
1) If the mA reading is 20 mA and the flow
meter display does not read
approximately 32, replace the Slot 11
2) If the mA reading is not 19.5 to 20.5,
13
Product TDS reading is not as
expected from previous
operational data or not in
agreement with portable TDS
Conductivity switch failure.
Check for 110 VAC between the switch outer
meter.
terminal screw and ground. If not found,
replace the switch.
PLC Slot 10 output card failure or display
Conduct BIT test and stop at the display test.
failure.
If the display does not count up, refer to Item
2 above.
Conductivity transmitter CT-501or
conductivity sensor CE-501A or 501B
not blank inside the Instrument Panel (WP
failure.
0043). If
this doesn't correct the problem
perform the following. With the TWPS
operating normally, open the
Instrument/Solenoid Panel to observe the
conductivity transmitter.
1) If the display is blank, replace the
2) If the WARNING CHECK STATUS
message flashes on the display, refer to
Conductivity Loop Status Checking in
0035 00-13