OPERATOR MAINTENANCE PROCEDURES
CONTROL INSTRUMENTS
Edit/Selection Screens: At the Edit/Selection screens the left and right arrow keys
o
move the cursor left or right in order to select digit for adjustment with up and
down arrow keys.
Up and down arrow keys: Depending on the type of displayed screen, these keys do the
-
following:
o Measure Screen: At the Measure screen the up and down arrow keys are non-
functional.
o Menu Screen: At the Menu screen the up and down arrow keys move the display
up or down between other same-level menu screens.
o Edit/Selection Screens: At the Edit/Selection screens the up and down arrow keys
adjust the selected digit value up or down, or move up or down between choices.
MF FEED FLOW TRANSMITTER FT-101
RO REJECT FLOW TRANSMITTER FT-401
PRODUCT FLOW TRANSMITTER FT-501
Figure 1. Transmitter Keypad.
Configure any of the three panel mounted flow transmitters as follows:
a. Press the MENU key to display a "MAIN MENU" screen.
b. If the "MAIN MENU/CONFIGURE" screen is not showing, use the up and down arrow
keys to display it.
c. Press the ENTER key to display Configure/Set Output.
d. Press the down arrow key until Configure/Language screen appears.
e. Press ENTER to verify that the language setting is at English. Select English if it is not,
then press ESC to exit.
2. Configure the sensor:
a. Set the Multiplier (for displayed flow rate).
1) With the Configure/Language screen displayed, press down arrow key once
to display Configure/Sensor.
2) Press the ENTER key to display Sensor/Set Multiplier.