ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
POWER DISTRIBUTION SYSTEM
THIS SECTION COVERS:
Replace
INITIAL SETUP:
Maintenance Level
Unit
Tools
Marine Corps: Common No. 1 Tool Set (WP 0075)
References:
Refer to TM 10-4610-309-24P for repair parts information
Personnel Required
One Maintainer
Equipment Condition
TWPS in Standby Shutdown Without Draining Down
Army TWPS: Generator off and TWPS main breaker off
Marine Corps TWPS: TWPS disconnected from power source
GENERAL:
This work package contains information and instructions for replacing components of the Power
Distribution System. The procedures covered in this work package include:
Circuit Breaker With Auxiliary Switch Replacement
Circuit Breaker Replacement
GFI Module Replacement
Contactor/Overload Relay/Surge Suppressor Replacement
Contactor/Surge Suppressor Replacement
Surge Arrester Replacement
Surge Arrester Assembly Replacement
Busbar Jumper Replacement
Surge Suppressor Replacement
125 Amp Main Power Circuit Breaker Replacement
Distribution Block Replacement
Power Connector Replacement
Light Outlet Replacement
Utility Outlet Replacement
Light Switch Replacement
Main Circuit Breaker Handle Replacement
0063 00-1