ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
DIRECT SUPPORT MAINTENANCE PROCEDURES
TACTICAL WATER PURIFICATION SYSTEM (TWPS) SKID, FLAT RACK,
THIS SECTION COVERS:
Remove, Install, Replace, Repair
INITIAL SETUP:
Maintenance Level
Direct Support
References
TM 9-237 Welding Theory and Application
TM 43-0139 Painting Instructions
Personnel Required
Two
Equipment Condition
TWPS in extended shutdown
GENERAL:
The procedures covered in this work package include:
TWPS Removal from and Installation into the Flat Rack (A-TWPS Only)
TQG Replacement (A-TWPS Only)
Frame, Tie-Down, and Lift Provision Repair
REMOVE AND INSTALL
TWPS Removal from and Installation into the Flat Rack (A-TWPS Only):
Parts:
Horseshoe shim (TM 10-4610-309-24P or TM 10802A-24P/2)
Materials:
Sealing Compound PR-1440 B-2 (WP 0079, Table 1, item 37)
Equipment Condition:
Remove and reinstall the A-TWPS unit from and into the flat rack as follows:
NOTE
The A-TWPS flat rack and TWPS unit are serialized together as a unit. The TWPS
unit would not typically be removed from the flat rack and replaced with another
TWPS unit.
0071 00-1