TM 10-4610-310-14
0013 00
LONG TERM SHUTDOWN/PRESERVATION - continued
7. Disconnect feed fabric hose (green) from booster pump discharge fitting and from the UF feed inlet.
8. Disconnect the backwash hose (yellow) from backwash inlet on the UF module and connect it to the UF inlet.
BOOSTER PUMP
DISCHARGE FITTING
BACKWASH INLET
UF INLET
FILTRATE OUTLET O1
Figure 9. UF Hose Connection.
9. Disconnect the hose (yellow) from the UF filtrate bag outlet O1 and connect it to the cleaning tank outlet
(located beneath the cleaning tank). This will allow the BACKWASH pump to draw from the cleaning tank.
10. Disconnect high-pressure hose to the RO inlet. Plug the hose on both ends with the union adapter.
11. Attach the cleaning adapter from the BII box to the RO inlet. See Figure 10.
RO INLET
FITTING
CLEANING ADAPTER
BACKWASH PUMP
OUTLET HOSE
Figure 10. Cleaning Adapter Connection.