TM 10-4610-310-14
0043 00
HIGH pH CLEANING PROCEDURE continued
WARNING
When using any chemicals, follow all safety regulations. Always wear eye protection as a minimum.
When handling corrosive chemicals wear goggles and protective clothing and gloves. Failure to follow
this warning may result in injury or death to personnel.
WARNING
Always consult and understand the Material Safety Data Sheets (MSDS) for the chemicals
you are using. Failure to follow this warning may result in injury or death to personnel.
5. Mix in one pre-measured box of M326 high pH cleaner. The cleaner box is marked with a black cross.
6. Mix well with the stirring paddle from the Basic Issue Items (BII) box.
7. Ensure that all the chemicals are dissolved and well mixed before circulating the solution to the RO
membrane elements.
CAUTION
Do not allow the 2000-watt immersion heater element to contact the side of the tank.
8. Remove immersion heater with bracket from BII box. Loosen wing nut on bracket. Turn bracket
approximately 90 degrees. Tighten wing nut.
9. Install the immersion heater into cleaning tank. Use bracket to support the immersion heater on the side of
the tank. Hang heater over module frame. See Figure 3.
CLEANING
TANK
WINGNUT
BRACKET
Figure 3. Immersion Heater Installed in Cleaning Tank.