TM 10-4610-310-14
0066 00
MALFUNCTION
TEST/INSPECTION
CORRECTIVE ACTION
Open the control panel. Inspect
Repair or replace damaged wire. If
functioning (not allowing the
all wiring for looseness and
voltage is present at the inlet but not at
pressureized air to enter the air
damage. Measure voltage at wire
the outlet replace SP 15. If not proceed
cylinder)
28 to ground or any neutral (wire
- continued
3) at the inlet and the outlet of
surge suppressor (SP 15).
Measure voltage (120 VAC) at
If voltage is present at the inlet but not at
the inlet (22 and 3) and the outlet
the outlet replace CR2. If not proceed to
(28 and 3) of control relay 2
next step.
(CR2)
Ensure that the output light 0 is
on at the PLC. This light will be
on when power is sent to
6. moisture inside the pressure
Ensure that the rubber plug is
Remove the plug to allow the moisture to
gauge
present on top of the pressure
escape and reinstall it. Replace if
gauge
missing.
7. Shutoff assembly
Engage the manual override. SeeWP
malfunctioning -no spare parts
0066 00-2