TM 10-4610-310-14
0089 00
Backwash Pressure Gauge
1. Refer to Figure 4 for this procedure section.
2. Install elbows (1) if necessary.
3. Install gauge (5) in the panel.
4. Install tubing (2).
5. Install screws (6), washers (4), and nuts (3).
Temperature Gauge
1. Refer to Figure 6. for this procedure section.
2. Install temperature gauge (1) onto the thermowell fitting (2).
3. Install thermowell fitting (2) into piping (3) if necessary.
END OF WORK PACKAGE
0089 00-5 / 6 blank