TM 10-4610-310-14
0091 00
REMOVAL
WARNING
Use at least two personnel to position the UF module on its side if repair or removal of the
protective grille is required. Make sure surface is flat and void of obstructions.
1. Position the UF module on its side to obtain access to the protective grille. Do not lay module on fabric filtrate
tank T2. See Figure 2.
THIS SIDE DOWN
ATTACHMENT
POINTS
PROTECTOR
GRILLE
Figure 2. Protective Grille.
2. Remove eight machine screws, flat washers, and hex lock nuts from eight brackets on base of UF module.
See Figure 3.
SCREW,
WASHER, NUT
(8 PLACES)
BRACKET
(8 PLACES)
PROTECTOR
GRILLE
Figure 3. Protective Grille Attachment.
3. Remove protective grille from eight brackets on bottom of UF module