2. With UF module on its side, place protective grille over eight brackets on bottom of frame. Do not lay module
on fabric filtrate tank T2.
3. Align eight holes in protective grille with brackets.
4. Install eight machine screws, flat washers, and hex nuts through protective grille and brackets. See Figure 3.
5. Tighten screws securely.
CAUTION
Use at least two personnel to position the UF module in the upright position. Make sure surface
is flat and void of obstructions to prevent damage to protective grille.
6. Place the UF module in the upright operational position. See Figure 2.
7. Reconnect water hoses to the UF module and the electrical cable to the control panel. See Figure 1
a. Reconnect 25-foot electrical cable 6 to the receptacle J6 on the control module.
b. Reconnect 25-foot hose (green) to the feed inlet (connection H) coupler.
c.
Reconnect 50-foot hose (red) to the reject outlet 1 (connection K).
d. Reconnect 10-foot hose (yellow) to the outlet O1 on filtrate tank T2 (to BACKWASH pump).
e. Reconnect 10-foot hose (yellow) to the backwash inlet (connection P).
f.
Reconnect 12-foot hose (orange) to the filtrate tank T2 outlet O2 (to high-pressure pump).
END OF WORK PACKAGE
0091 00-3 / 4 blank