TM 10-4610-310-14
0096 00
Removal continue
Remove the conduit (9) from the junction box (8). See Figure 4.
5.
Remove the conduit (9) from the low-pressure switch (4) at the top nut (3). Pull wires out from the conduit
6.
(9).
SOME DETAILS
OMITTED FOR
CLARITY
Figure 4. Low-Pressure Switch Removal.
Remove tubing from tee fitting (7).
7.
Remove screws (5), nuts (1) and washers (2) from low-pressure switch.
8.
Remove tee fitting (7) and adapter (6).
9.
NOTE
Tee fitting cannot be removed from the switch until the switch is removed from mounting panel.
INSTALLATION
High-Pressure Switch
1. Install the adapter (3) and elbow fitting (4) on the high-pressure switch (6).
2. Install high-pressure switch (6) and secure with screws (5), nuts (1), and washers (2). See Figure 3.
3. Feed the wire through the conduit (8) and into the junction box (9).
4. Connect wires 2 and 6 on the terminal block (TB1). See Figure 2.
5. Secure the conduit (8) on the high-pressure switch (6) and on the junction box (9).
6. Install the tubing onto the elbow fitting (4).