TM 10-4610-310-14
0102 00
Installation
1. Place magnetic contactor into mounting socket.
2. Press down on magnetic contactor to lock into place.
3. Connect four wires to magnetic contactor. Observe number tags and prior notes for proper connection.
Tighten securely.
TERMINAL BOARD (TB1)
Removal
1. Make note of number and location of all wires on nine terminal blocks. See Figure 4.
2. Remove wires and jumper wires from terminal blocks.
3. Remove screw from terminal block end stop on terminal block mounting rail.
4. Remove 10-pole center jumper.
5. Remove terminal blocks from terminal block mounting rail.
Installation
1. Install terminal blocks on terminal block mounting rail.
2. Install 10-pole center jumper.
3. Install screw in terminal block end stop on terminal block mounting rail. Tighten securely.
4. Connect wires and jumper wires to nine terminal blocks. Observe number tags and prior notes for proper
connection.
CONTROL RELAY (CR2)
Removal
1. Make note of number and locations of wires on control relay. See Figure 4.
2. Remove five wires from control relay.
3. Use a screwdriver and press down on release clip.
4. Pull up and remove control relay from mounting socket.
Installation
1. Place control relay into mounting socket.
2. Press down on control relay to lock into position.
3. Connect wires to control relay. Observe number tags and prior notes for proper connection.
JAM NUT RECEPTACLE (J1 J9)
Removal
1. Make note of wire number and location of all wires on rear of jam nut receptacle. See Figure 1.
2. Remove wire contacts from receptacle.
3. Number of pins varies depending on connector/receptacle, 3 to 10 wires.
4. Remove safety wire from jam nut. Discard safety wire.
5. Remove jam nut on front of receptacle.
6. Remove receptacle from cutout on side of control module.
0102 00-11