TM 10-4610-310-14
0102 00
Installation
1. Insert base onto the DIN mounting rail (engage the top of rail first then bottom of rail).
2. Reconnect the wires and replace the surge suppressor.
MOTOR CONTROLLER (SS1 SS3)
Removal
1. Make note of number and location of four wires on motor controller. See Figure 4.
2. Remove four wires from motor controller.
3. Insert screwdriver into release clip. Press clip down to release motor controller from mounting bracket.
4. Grasp motor controller and pull out.
Installation
1. Place motor controller on mounting bracket by inserting the top first and rotating downwards until it locks.
2. Connect four wires to motor controller. Observe number tags and prior notes for proper connection.
CIRCUIT BREAKER (CB2)
Removal
1. Make note of the number and location of wires on circuit breaker. See Figure 4.
2. Remove two wires from circuit breaker.
3. Press release clip with screwdriver.
4. Pull up and remove circuit breaker.
Installation
1. Connect two wires to circuit breaker. Observe number tags and prior note for proper connection.
2. Place circuit breaker on mounting bracket.
3. Press down to lock circuit breaker into position.
CIRCUIT BREAKER BLOCK (CB3)
Removal
1. Make note of number and location of four wires on circuit breaker mounting bracket. See Figure 3.
2. Remove wires from circuit breaker block.
3. Press release clip with screwdriver
4. Pull up and remove circuit breaker from mounting bracket.
Installation
1. Place circuit breaker block on mounting bracket.
2. Press down to lock circuit breaker into position.
3. Connect four wires to circuit breaker block. Observe number tags and prior notes for proper connection.
PROGRAMMABLE LOGIC CONTROLLER (PLC)
Removal
The PLC has 14 input and 12 output. Inputs 15 through 23 are spares, outputs 13 through 16 are spares. See
Figure 4.
0102 00-8