TM 10-4610-310-14
DIRECT SUPPORT/GENERAL SUPPORT MAINTENANCE
LIGHTWEIGHT WATER PURIFIER
CONTROL MODULE
SURGE ARRESTOR (SP1)
REMOVAL/INSTALLATION
INITIAL SETUP
Materials/Parts
Tools
Box assembly, junction, (PN 2203904000)
Shop equipment, automotive, common 1 and 2
Block, terminal, 15-circuit, (PN 1492-WM3)
Equipment Condition Required
All equipment de-energized
GENERAL
This work package contains information and instructions for removal and installation of the surge arrestor (SP1) in
the control module used on the Lightweight Water Purifier (LWP).
REMOVAL
1. Remove wires 60 and 61 from lower connections of circuit breaker (CB 1). See Figure 1.
2. Remove neutral and ground wires from end section on the right of motor controller (M1). Make note of
their locations.
3. Remove all wire ties from the wires coming from the surge arrestor connection.
INSTALLATION
1. Install wires 60 and 61 on the lower connections of circuit breaker (CB1). See Figure 1.
2. Install neutral and ground wires from end section on the right of motor controller (M1).
3. Secures all wires coming from the sure arrestor connection with wire ties.
0132 00-1