TM 5-3800-205-23-3
FUEL LEVEL SENDING UNIT AND DIAL SENSOR REPLACEMENT - CONTINUED
0007 00
DIAL SENSOR REMOVAL
NOTE
Ensure area around dial sensor and fuel tank is clear of dirt and debris.
1.
Disconnect electrical connector (2) from harness connector (3).
2.
Remove two screws (5) and dial sensor (1) from fuel level sending unit (4).
2,3 (HIDDEN)
1
4
5
DIAL SENSOR INSTALLATION
1.
Install dial sensor (1) on fuel level sending unit (4) with two screws (5) and tighten.
2.
Connect electrical connector (2) to harness connector (3).