TM 5-3800-205-23-3
BACKUP ALARM REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Maintenance Level
Equipment Condition
Machine parked on hard, level surface (TM 5-3800-
Unit
205-10-2)
Tools and Special Tools
Tank lowered to ground (TM 5-3800-205-10-2)
Parking brake engaged (TM 5-3800-205-10-2)
Wheels chocked (TM 5-3800-205-10-2)
Materials/Parts
Battery disconnect switch in OFF position (TM 5-
3800-205-10-2)
REMOVAL
1.
Open rear access panel.
NOTE
Cut tiedown straps and discard. Use new tiedown straps on installation.
2.
Disconnect backup alarm connector (8) from harness connector (7).
3.
Remove two nuts (2), four washers (3), and two screws (4), and remove alarm (1) and ground wire (5) from bracket (6).
2,3,4 5
1
6
390-1997
8
7