TM 5-3800-205-23-3
WATER TANK ACCESS COVER MAINTENANCE
THIS WORK PACKAGE COVERS
Removal, Disassembly, Assembly, Installation
INITIAL SETUP
Personnel Required
Maintenance Level
Two
Unit
Equipment Condition
Tools and Special Tools
Machine parked on hard, level surface (TM 5-3800-
205-10-2)
Gloves, work
Tank lowered to ground (TM 5-3800-205-10-2)
Parking brake engaged (TM 5-3800-205-10-2)
Materials/Parts
Wheels chocked (TM 5-3800-205-10-2)
Gasket
Battery disconnect switch in OFF position (TM 5-
Pin, cotter (3)
3800-205-10-2)
Seal, rubber
Water tank access cover opened (TM 5-3800-205-
10-2)
Washer, lock (25)
WARNING
DO NOT enter water tank. Tank interior is a confined space and therefore hazardous to enter. If tank
entry becomes absolutely necessary, contact your local safety office and obtain a confined space entry
permit. Requirements of 29 CFR 1910.145(d)(2) (reference 17), as well as any local requirements, must
be followed. Failure to follow this warning may result in injury or death due to oxygen deprivation.
NEVER drink water contained in water distributor tank. Water contained or dispensed from tank is
NON-POTABLE. Drinking non-potable water could result in illness or death.
Do NOT step on water tank access cover grate. Failure to follow this warning may result in injury to
personnel.
Wear work gloves when performing maintenance on access cover, due to sharp edges of grate and cutter
bar. Failure to do so may result in injury to personnel.