TM 5-3800-205-23-3
WATER TANK FOOT VALVE ASSEMBLY REPLACEMENT - CONTINUED
0032 00
REMOVAL - CONTINUED
7
6
8
10
9
INSTALLATION
1.
Ensure plate (1) is clean of debris.
2.
Install foot valve (9) and flange assembly (7) to body assembly (8) with five bolts (6).
3.
Apply a coat of grease to new O-ring (4) and sealing surface of water tank. Position O-ring in groove of water tank.
4.
Position plate (1) so that plate is centered on jack and position jack and plate below water tank. Raise jack.
NOTE
Ensure that O-ring remains in groove of water tank.
5.
Install plate (1) on water tank with 12 new lockwashers (3) and bolts (2).
6.
Lower and remove jack.
7.
Tighten 12 bolts (2).
8.
Apply a thin coat of sealing compound to threads of plug (5) and install plug to center of plate (1).
9.
Remove blocking and lower water tank (TM 5-3800-205-10-2).
END OF WORK PACKAGE
0032 00-3