TM 5-3800-205-23-3
WATER PUMP MAINTENANCE - CONTINUED
0038 00
REMOVAL - CONTINUED
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during the
procedure. Ensure that any lifting device used is in good condition and of suitable load capacity. Keep clear
of heavy parts supported only by lifting device. Failure to follow this warning may result in death or injury
to personnel.
NOTE
Power head weighs 115 lb (52 kg).
5.
With assistance, remove power head (2) assembly from pump housing (4).
DISASSEMBLY
CAUTION
Use care when handling power head and diffuser. Diffuser is loose and could fall from power head, resulting
in damage to diffuser.
1.
Remove diffuser (7) and gasket (8) from adapter (3). Remove and discard O-ring seal (9) from diffuser.
8
7
3
390-1575
9
0038 00-3