TM 10-4320-317-13
3-5. MAINTENANCE OF HOSE ASSEMBLIES. - (Cont)
(d) Loosen nuts (4) and bolts (5) fully, between damps (6).
(e) Inspect for missing or damaged O-rings (7) on adapter (8). Replace missing or damaged O-rings (7).
(f) Apply anti-seize lubricant to O-rings (7).
(g) Insert hose end (3) between damps (6) and onto adapter (8).
(h) Tighten nuts (4) and bolts (5) alternately and evenly. Do not overtighten.
CAUTION
Do not overtighten nuts and bolts. Overtightening may damage O-rings and adapter causing leaks.
(3) Install female hose adapter assembly as follows (Figure 3-5):
Figure 3-5. Female Hose Adapter Assembly
NOTE
Always mark, score, and cut hose squarely. Do not leave ragged or uneven edges.
(a)
Cut end of hose (1) below damaged section. Remove damaged hose end (2).
3-8