TM 10-4610-232-34
REASSEMBLY. (Continued.)
(10)
Install valve (31), fitting (30), stainless steel tubing (29).
INSTALLATION
a.
Panel B.
(1)
Install eyebolt (28), support rod (20), washer (27), two nuts (26), five washers (25) and self-locking nut (24).
(2)
Mount panel on top of control cabinet and secure with two capscrews (21), two lockwashers (22), and two
washers (23).
(3)
Mount panel on support rod (20) and secure with nut (26), washer (27), washer (19), and nut (18).
(4)
Connect all plastic tubes (16) as tagged on tees (17) on the CARTRIDGE INLET/OUTLET PRESSURE
gage (59). Repeat for MEDIA INLET/OUTLET PRESSURE gage.
b.
Panel A.
(1)
Install eyebolt (15), support rod (7), washer (14), two nuts (13), five washers (12), and self-locking nut (11).
(2)
Mount panel on top of control cabinet and secure with two capscrews (8), two lockwashers (9), and two
washers (10).
(3)
Mount Panel A on support rod (7). Secure with washer (6) and nut (5).
(4)
Connect two plastic tubes (3) on tee (4).
(5)
Connect three high pressure lines (1) to selector switch (2).
2-112.4 Change 5